Arguments description for plugin ICA

plugin name: ica

argument requirement description
input_file <file> MANDATORY common argument
modality <eeg,eeg,ieeg> MANDATORY channel modality
comp <value> MANDATORY number of components
hp <value> OPTIONAL common hp argument.
lp <value> OPTIONAL common lp argument.
downsampling <flag> OPTIONAL Downsampling data before computing. Default is false
infomax_extended <flag> OPTIONAL Use the extended option for Infomax. Default is false.
skip_bad <flag> OPTIONAL Skip bad channels. Default is true.
skip_markers <marker name> OPTIONAL common argument. ICA will skip all the data sections marked by the specified marker.
use_markers <marker name> OPTIONAL common argument. ICA will only compute on data sections marked by the specified marker.

Examples

run ica on meg data, just 70 components and filtering data in the 1-100Hz band.

anywave --run ica --input_file d:\data\meg\megdata.meg --modality meg --comp 70 --hp 1 --lp 100