AnyWave:CLI H2
From WikiMEG
Arguments description for plugin H2
plugin name: h2
argument | requirement | description |
---|---|---|
input_file <file> | MANDATORY | common argument |
time_window <value> | MANDATORY | time window in seconds. |
step <value> | MANDATORY | step in seconds. |
max_lag <value> | MANDATORY | maximum lag in seconds. |
hp <value> | OPTIONAL | common hp argument. |
lp <value> | OPTIONAL | common lp argument. |
algorithm <r2,h2> | OPTIONAL | algorithm method to compute correlation. Default is h2. |
downsampling_factor <value> | OPTIONAL | Downsampling data before computing by factor. ie. if sampling rate is 1024Hz, a factor of 4 will downsample to 256Hz. Default is 1 (no downsampling) |
skip_markers <marker name> | OPTIONAL | common argument. ICA will skip all the data sections marked by the specified marker. |
use_markers <marker name> | OPTIONAL | common argument. ICA will only compute on data sections marked by the specified marker. |
output_dir <dir> | OPTIONAL | common argument. The result file will be placed in the specified directory path. |
output_prefix <string> | OPTIONAL | common argument. The result file will be prefixed using the specified string. |
Examples
run h2 on seeg data, using 1-100Hz band.
anywave --run h2 --input_file d:\data\seeg\data.eeg --time_window 4 --step 0.5 --max_lag 0.1 --hp 1 --lp 100
run with r2 method:
anywave --run h2 --input_file d:\data\seeg\data.eeg --algorithm r2 --time_window 4 --step 0.5 --max_lag 0.1 --hp 1 --lp 100