Arguments description for plugin H2

plugin name: h2

argument requirement description
input_file <file> MANDATORY common argument
time_window <value> MANDATORY time window in seconds.
step <value> MANDATORY step in seconds.
max_lag <value> MANDATORY maximum lag in seconds.
hp <value> OPTIONAL common hp argument.
lp <value> OPTIONAL common lp argument.
algorithm <r2,h2> OPTIONAL algorithm method to compute correlation. Default is h2.
downsampling <flag> OPTIONAL Downsampling data before computing. Default is false
infomax_extended <flag> OPTIONAL Use the extended option for Infomax. Default is false.
skip_bad <flag> OPTIONAL Skip bad channels. Default is true.
skip_markers <marker name> OPTIONAL common argument. ICA will skip all the data sections marked by the specified marker.
use_markers <marker name> OPTIONAL common argument. ICA will only compute on data sections marked by the specified marker.
output_dir <dir> OPTIONAL common argument. The result file will be placed in the specified directory path.
output_prefix <string> OPTIONAL common argument. The result file will be prefixed using the specified string.

Examples

run h2 on seeg data, using 1-100Hz band.

anywave --run h2 --input_file d:\data\seeg\data.eeg --time_window 4 --step 0.5 --max_lag 0.1 --hp 1 --lp 100

run with r2 method:

anywave --run h2 --input_file d:\data\seeg\data.eeg --algorithm r2 --time_window 4 --step 0.5 --max_lag 0.1 --hp 1 --lp 100